0 CAD 0.00
items in your cartto quote Checkout
Ooops no items were found.
Try something else.
Ok
Loading…
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL

Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger

1 In Stock
Item Code: 501-M9D-DL
Manufacturer Surgo Surgical Supply
Manufacturer Ref M9D-042-DL

Description

The M9D autoclave couldn’t be easier and is time tested for reliability. You simply load it set it and forget it. Select your cycle and the time is set for you. Press Start and the M9D fills with the correct amount of water. Once the sterilization process is complete, simply open the door to dissipate the steam and allow the instruments to dry.

Features

  • 9" x 15" Chamber
  • Steam Flush Pressure Pulse Air Removal System ensures proper steam penetration
  • Self Program Controls enable you to create different cycle parameters to meet specific instrument processing needs
  • Pre-programmed Controls for convenience
  • Easy to read LCD Display
  • One year warranty (parts and labour)
  • Includes Data Logger

Specifications

  • Overall length w/plug: 20.4" (51.8 cm)
  • Overall width: 15.3" (38.9 cm)
  • Overall height w/printer: 15.8" (40.1 cm)
  • Minimum Countertop area: 15.3" x 17.9" (38.9 cm x 45.4 cm)
  • Chamber:
    • 9" diameter (22.9 cm)
    • 15" depth (38.1 cm)
    • 3.5 gal. usable volume (13.4 liters)
  • Trays:
    • Two large 7.3"
    • W x 12" L x .8" D (18.6 cm x 30.5 cm x 2.2 cm)
    • Two small 5.6" W x 12" L x .8" D (14.3 cm x 30.5 cm x 2.2 cm)
    • Unit weight: 73 lbs. (33.1 kg)
    • Water reservoir capacity: 1.1 gal. (4.1 liters)
  • Electrical Requirements:
    • 115 VAC, 50/60 Hz, 15 Amps Single Phase
    • 115 VAC has 1425 watt tubular immersion heater
  • A separate (dedicated) circuit is recommended for this sterilizer

Data Logger

  • High capacity, detailed sterilizer data storage
  • Compatible with all M9 and M11 steam sterilizer models
  • Reliable USB-based data transfer
  • Data stored in PDF format

Specifications

Made In

US

Catalog Page Number

103

Brand

Midmark

Category

Midmark M9 Autoclaves

Starting from
CAD 6,821.25 / EA
/
1
LIST PRICE CAD 7,905.00
14%
- +
Compare
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL
Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger = 501-M9D-DL

Ritter M9D Ultraclave® Automatic Sterilizer With Manual Door and Data Logger

1 In Stock
Item Code: 501-M9D-DL
Manufacturer Surgo Surgical Supply
Manufacturer Ref M9D-042-DL
Starting from
CAD 6,821.25 / EA
/
1
LIST PRICE CAD 7,905.00
14%
- +
Compare

Description

The M9D autoclave couldn’t be easier and is time tested for reliability. You simply load it set it and forget it. Select your cycle and the time is set for you. Press Start and the M9D fills with the correct amount of water. Once the sterilization process is complete, simply open the door to dissipate the steam and allow the instruments to dry.

Features

  • 9" x 15" Chamber
  • Steam Flush Pressure Pulse Air Removal System ensures proper steam penetration
  • Self Program Controls enable you to create different cycle parameters to meet specific instrument processing needs
  • Pre-programmed Controls for convenience
  • Easy to read LCD Display
  • One year warranty (parts and labour)
  • Includes Data Logger

Specifications

  • Overall length w/plug: 20.4" (51.8 cm)
  • Overall width: 15.3" (38.9 cm)
  • Overall height w/printer: 15.8" (40.1 cm)
  • Minimum Countertop area: 15.3" x 17.9" (38.9 cm x 45.4 cm)
  • Chamber:
    • 9" diameter (22.9 cm)
    • 15" depth (38.1 cm)
    • 3.5 gal. usable volume (13.4 liters)
  • Trays:
    • Two large 7.3"
    • W x 12" L x .8" D (18.6 cm x 30.5 cm x 2.2 cm)
    • Two small 5.6" W x 12" L x .8" D (14.3 cm x 30.5 cm x 2.2 cm)
    • Unit weight: 73 lbs. (33.1 kg)
    • Water reservoir capacity: 1.1 gal. (4.1 liters)
  • Electrical Requirements:
    • 115 VAC, 50/60 Hz, 15 Amps Single Phase
    • 115 VAC has 1425 watt tubular immersion heater
  • A separate (dedicated) circuit is recommended for this sterilizer

Data Logger

  • High capacity, detailed sterilizer data storage
  • Compatible with all M9 and M11 steam sterilizer models
  • Reliable USB-based data transfer
  • Data stored in PDF format

Specifications

Made In

US

Catalog Page Number

103

Brand

Midmark

Category

Midmark M9 Autoclaves

SEARCH ×